Not a valid Time
This is a required field.
Full Face Shield, TGA, 32 x 24.2cm, Anti Fog with Foam Pad and Elastic Head Band, Blue

Livingstone Full Face Shield, TGA, 32 x 24.2cm, Anti Fog with Foam Pad and Elastic Head Band, Blue, Each - Clearance

Disposable electrode, 36x40 mm (oval), SSC sensor, snap connection, FOAM support

Disposable electrode, 36x40 mm (oval), SSC sensor, snap connection, FOAM support, for adults Pack Of 2000 - Clearance

Disposable electrode, 28x44 mm, SSC sensor, snap connection, FOAM support, liquid gel-Pack Of 50 - Clearance

Regular Price $8.03 Special Price $5.62 $5.11

FIAB disposable pregelled electrodes for ECG, have features that make
them absolutely reliable during signal recording in rest tests. The model
F9047 is used also recording in stress test and for Holter monitoring.
They are compatible with different ECG devices on the market. After
opening, the pouch can be folded to ensure a better preservation of the
electrodes that remain inside. The products are Latex-free.

Availability: In stock
SKU
ELECTR-39-clearance
 

FIAB disposable pregelled electrodes for ECG, have features that make
them absolutely reliable during signal recording in rest tests. The model
F9047 is used also recording in stress test and for Holter monitoring.
They are compatible with different ECG devices on the market. After
opening, the pouch can be folded to ensure a better preservation of the
electrodes that remain inside. The products are Latex-free.

CARATTERISTICHE TECNICHE – TECHNICAL FEATURES
MODELLO – MODEL F9047 F9047/4F F9047/4FL
DESCRIZIONE – DESCRIPTION Elettrodo monouso per ECG con
gel liquido e captatore Ag/AgCl
connessione a clip
ECG disposable electrode with
liquid gel and SSC sensor – clip
connection
Elettrodo monouso per ECG
con gel solido e adattatore
per spinotto 4mm
ECG disposable electrode
with solid gel and adapter for
4mm plug connection
Elettrodo monouso per ECG
con gel liquido e adattatore per
spinotto 4mm
ECG disposable electrode with
liquid gel and adapter for 4mm
plug connection
UTILIZZO - USE Adulti e Pediatrico – Adult and Pediatric
MATERIALE - MATERIAL FOAM (schiumato medicale in PE)
SPESSORE - THICKNESS 1 mm
DIMENSIONE - DIMENSIONS 32 x 44 mm 28 x 44 mm
ADESIVO - ADHESIVE Resina sintetica ipoallergenica (biocompatibile secondo la Norma ISO 10993/1)
Hypoallergenic (Biocompatible according to ISO 10993/1 Standard) syntethic resin
COLLEGAMENTO - CONNECTION Cavetto a snap - snap cable Cavetto con maschio 4mm - 4mm plug cable
MATERIALE CONDUTTORE
CONDUCTIVE MATERIAL Ag/AgCl – Argento/Cloruro di Argento - SSC
GEL
Gel medicale biocompatibile
allo stato liquido
Medical liquid gel biocompatible
Gel medicale biocompatibile
allo stato solido
Medical solid gel biocompatible
Gel medicale biocompatibile
allo stato liquido
Medical liquid gel biocompatible
CONFORMITÀ ALLA NORMATIVA
COMPLIANCE TO STANDARDS
Direttiva 93/42/CEE (D.L. 46/97) e succ. modifiche. Dispositivo medico in classe I.
ANSI/AAMI EC12:2000 “Disposable ECG Electrodes”
Directive 93/42/EEC and amendments. Class I medical device.
ANSI/AAMI EC12:2000 “Disposable ECG Electrodes”
CONFEZIONAMENTO - PACKAGING
CONFEZIONE PRIMARIA
PRIMARY PACKAGING
50 pezzi in busta termosaldata
50 pcs in thermo-sealed pouch
CONFEZIONE DI VENDITA
SALE PACKAGING
1200 pezzi / 1200 pcs
(24 buste) in scatola di cartone
(24 pouches) in carton box
1000 pezzi / 1000 pcs
(20 buste) in scatola di cartone
(20 pouches) in carton box
IMMAGAZZINAMENTO
STORAGE
Temperatura:+5 ÷ +30 °C – Umidità relativa: 20% ÷ 80 %
Temperature +5 ÷ +30 °C - Relative humidity: 20% ÷ 80 %
F9047, F9047/4FL
(gel liquido/liquid gel)
30 mesi dalla data di produzione se conservati correttamente ***
SCADENZA 30 months from production date if correctly stored***
EXPIRY F9047/4F
(gel solido/solid gel)
36 mesi dalla data di produzione se conservati correttamente ***
36 months from production date if correctly stored***
TEST ELETTRICI - ELECTRIC TESTS (Standard A.A.M.I.)
Specifica ANSI/AAMI EC12:2000 ANSI/AAMI EC12:2000
Specification Limite AAMI - AAMI Limits Risultato dei test - Test Results
Valor medio dell’impedenza misurata a 10Hz per 12 paia di elettrodi
Average value of 10-Hz impedance for 12 electrode pairs 2 kΩ 60 Ω
Impedenza della singola coppia - Individual pair impedance 3 kΩ 65 Ω
Offset Voltage 100 mV 1,4 mV
Instabilità dell’offset combinato con il rumore intrinseco
Combined offset instability and internal noise 150 μV 1 μV
Tensione residua dopo la defibrillazione - Defibrillation overload recovery 100 mV 15 mV
Variazione della polarizzazione - Rate of change of polarization 1 mV/s 0,6 mV/s
Impedenza a 10 Hz dopo il test - After test, 10-Hz electrode impedance 3 kΩ 50 Ω
Tolleranza alla corrente di bias: Tensione di Offset in continua
Bias current tolerance: DC voltage offset 100 mV 16,1 mV
***Si consiglia l’utilizzo degli elettrodi entro 30gg dall’apertura della busta / We recommend the use of electrodes within 30 days of opening bag